Globalepolicy.org is a free to access global medical news service for the consumer, professional and researcher.
Our adviser: Drugs Infromation online


             
 

Background: A treatment algorithm and screening examination have been developed to guide patient management and prospectively determine potential for highly active individuals to succeed with nonoperative care after anterior cruciate ligament rupture.

Objective: To prospectively characterize and classify the entire population of highly active individuals over a 10-year period and provide final outcomes for individuals who elected nonoperative care.

Methods: Inclusion criteria included presentation within 7 months of the index injury and an International Knee Documentation Committee level I or II activity level before injury. Concomitant injury, unresolved impairments, and a screening examination were used as criteria to guide management and classify individuals as noncopers (poor potential) or potential copers (good potential) for nonoperative care.

Results: A total of 832 highly active patients with subacute anterior cruciate ligament tears were seen over the 10-year period; 315 had concomitant injuries, 87 had unresolved impairments, and 85 did not participate in the classification algorithm. The remaining 345 patients (216 men, 129 women) participated in the screening examination a mean of 6 weeks after the index injury. There were 199 subjects classified as noncopers and 146 as potential copers. Sixty-three of 88 potential copers successfully returned to preinjury activities without surgery, with 25 of these patients not undergoing anterior cruciate ligament reconstruction at the time of follow-up.

Conclusion: The classification algorithm is an effective tool for prospectively identifying individuals early after anterior cruciate ligament injury who want to pursue nonoperative care or must delay surgical intervention and have good potential to do so.



NAVIGATION


         

 

Background: Most biomechanical studies for evaluation of the structural properties of meniscal repairs have been performed in tensile loading scenarios perpendicular to the circumferential meniscal fibers. However, meniscal repair constructs are also exposed to shear forces parallel to the circumferential meniscal fibers during healing, particularly in the midportion of the meniscus.

Hypothesis: Material properties of meniscal repair devices cannot be extrapolated from tensile to shear load scenarios.

Study Design: Controlled laboratory study.

Methods: In 84 harvested and isolated bovine lateral menisci following removal of adjacent soft tissue, a standardized vertical lesion was set followed by repair using all-inside flexible (FasT-Fix, FasT-Fix AB, RapidLoc) and rigid (Meniscus Screw, Meniscus Arrow) meniscal repair devices. Vertical and horizontal 2.0 Ethibond sutures were used as controls. The repaired meniscal construct was tested in a tensile (parallel to the axis of the tested repair device) and shear load scenario (perpendicular to the axis of the tested repair device) at 5 mm/min and 37°C environmental temperature. Maximum load to failure, stiffness, and failure mode were recorded.

Results: The absolute load to failure values of each repair device in the shear scenario were only marginally different from the tensile load scenario. However, the stiffness of several tested devices was markedly reduced in the shear scenario. In both scenarios, large differences of the load to failure and the stiffness between the implant types up to 5-fold were found (P < .05). The failure mode of several all-inside flexible repair devices was different in the shear versus tensile load scenario, while the failure mode of the rigid systems was similar in both scenarios.

Conclusion: All-inside meniscal repair devices exposed to shear load scenarios have comparable maximum loads to failures as tensile load scenarios. However, the stiffness of the majority of the flexible meniscal repair implants in a shear load scenario is markedly reduced. The applied scenario also affects the failure mode in several flexible meniscal repair devices.

Clinical Relevance: Meniscal repair devices with sufficient stiffness and stability against shear loads may be favored for meniscal repair, especially within the midportion of the meniscus where shear loads occur during healing.




May 2012
Mon Tue Wed Thu Fri Sat Sun
« Apr    
 123456
78910111213
14151617181920
21222324252627
28293031