Globalepolicy.org is a free to access global medical news service for the consumer, professional and researcher.
Our adviser: Drugs Infromation online


             
 

Background: A treatment algorithm and screening examination have been developed to guide patient management and prospectively determine potential for highly active individuals to succeed with nonoperative care after anterior cruciate ligament rupture.

Objective: To prospectively characterize and classify the entire population of highly active individuals over a 10-year period and provide final outcomes for individuals who elected nonoperative care.

Methods: Inclusion criteria included presentation within 7 months of the index injury and an International Knee Documentation Committee level I or II activity level before injury. Concomitant injury, unresolved impairments, and a screening examination were used as criteria to guide management and classify individuals as noncopers (poor potential) or potential copers (good potential) for nonoperative care.

Results: A total of 832 highly active patients with subacute anterior cruciate ligament tears were seen over the 10-year period; 315 had concomitant injuries, 87 had unresolved impairments, and 85 did not participate in the classification algorithm. The remaining 345 patients (216 men, 129 women) participated in the screening examination a mean of 6 weeks after the index injury. There were 199 subjects classified as noncopers and 146 as potential copers. Sixty-three of 88 potential copers successfully returned to preinjury activities without surgery, with 25 of these patients not undergoing anterior cruciate ligament reconstruction at the time of follow-up.

Conclusion: The classification algorithm is an effective tool for prospectively identifying individuals early after anterior cruciate ligament injury who want to pursue nonoperative care or must delay surgical intervention and have good potential to do so.



NAVIGATION


         

 

Background: The accuracy of meniscal measurement methods is still in debate.

Hypothesis: The authors’ protocol for radiologic measurements will provide reproducible bony landmarks, and this measurement method of the lateral tibial plateau will correlate with the actual anatomic value.

Study Design: Controlled laboratory study.

Methods: Twenty-five samples of fresh lateral meniscus with attached proximal tibia were obtained during total knee arthroplasty. Each sample was obtained without damage to the meniscus and bony attachment sites. The inclusion criterion was mild to moderate osteoarthritis in patients with mechanical axis deviation of less than 15°. Knees with lateral compartment osteoarthritic change or injured or degenerated menisci were excluded. For the lateral tibial plateau length measurements, the radiographic beam was angled 10° caudally at neutral rotation, which allowed differentiation of the lateral plateau cortical margins from the medial plateau. The transition points were identified and used for length measurement. The values of length were then compared with the conventional Pollard method and the anatomic values. The width measurement was done according to Pollard’s protocol. For each knee, the percentage deviation from the anatomic dimension was recorded. Intraobserver error and interobserver error were calculated.

Results: The deviation of the authors’ radiographic length measurements from anatomic dimensions was 1.4 ± 1.1 mm. The deviation of Pollard’s radiographic length measurements was 4.1 ± 2.0 mm. With respect to accuracy—which represents the frequency of measurements that fall within 10% of measurements—the accuracy of authors’ length was 98%, whereas for Pollard’s method it was 40%. There was a good correlation between anatomic meniscal dimensions and each radiologic plateau dimensions for lateral meniscal width (R2 = .790) and the authors’ lateral meniscal length (R2 = .823) and fair correlation for Pollard’s lateral meniscal length (R2 = .660). The reliability of each radiologic measurement showed good reliability (intraclass correlation coefficients, .823 to .973). The authors tried to determine the best-fit equation for predicting meniscal size from Pollard’s method of bone size, as follows: anatomic length = 0.52 x plateau length (according to Pollard’s method) + 5.2, not as Pollard suggested (0.7 x Pollard’s plateau length). Based on this equation—namely, the modified Pollard method—the percentage difference decreased, and the accuracy increased to 92%.

Conclusion: Lateral meniscal length dimension can be accurately predicted from the authors’ radiographic tibial plateau measurements.

Clinical Relevance: This study may provide valuable information in preoperative sizing of lateral meniscus in meniscal allograft transplantation.




May 2012
Mon Tue Wed Thu Fri Sat Sun
« Apr    
 123456
78910111213
14151617181920
21222324252627
28293031